News

Bamo CC1

– For swimming pool water monitoring
– Range: from 0.01 up to 10 ppm
– Output signal: 4-20 mA
– Pressure limit: 0.5 bar as a maximum
– Unnecessary zero adjustment

Bamo CP2-1

– For swimming pool or drinkable water
– Range: from 0.01 up to 10 ppm
– Output signal: 4-20 mA
– Pressure limit: 0.5 bar as a maximum
– Unnecessary zero adjustment

Bamo CS2-3

– For drinkable water monitoring
– Range: from 0.01 up to 10 ppm
– Output signal: 4-20 mA
– Pressure limit: 0.5 bar as a maximum
– Unnecessary zero adjustment

Bamochlor 192 open cell

– Open cell amperometric method
– Electrochemical cell
– Self cleaning
– Flow adjustment
– Wetted parts are of PVC and PMMA
– pH electrode by insertion, permanently or not

Bamophox 192

– Alphanumeric back lighted LCD display
– Friendly using menu
– Ranges
      from 0 to 5 mg/l for free chlorine
      -20…+160°C for temperature
– 2 analogical outputs 0/4-20mA, galvanic insulated
– 3 relay outputs (Normally Open contacts)
– 1 relay output for system alarm
– 1 input to switch on Stand-by the regulation
– 2 models available:
      Panel mounting 72 x 144
      Wall mounting IP 65

– OPTION
Extension for a 2nd measurement input

Bamophox 194

– Alphanumeric back lighted LCD display
– Friendly using menu
– 1 sensor input (4-20 mA or 0/-2 V)
– Parameters according to the sensor in use:
free chlorine, total chlorine, chlorine dioxide,
ozone, hydrogen peroxide, peracetic acid
– 2 analogical outputs 0/4-20 mA, galvanic insulated
– 3 relay outputs
– 1 relay for default or timer
– 1 flow controller input
– 2 models or panel mounting or wall mounting

OPTIONS:
RS 422/ J-BUS + Logger
Extension monitor for a second parameter

Bamo BS BC

– Resistivity and Conductivity probes
– Cell factors 0.1 and 0.01
– Reliability and sturdiness
– Construction: Stainless Steel and PTFE, PVC
– Also to be use with the BAMOPHOX

Bamo TOR

– Process measurement
on line
or by immersion
– For waste liquids
– Wide range of applications
– Large scales: from 0-2 to 0-2000 mS
– Probe material: NORYL

Bamophox 319 ML-DB

– 2 independent sensors
      Input 1: range 0…20 MΩ
      Input 2: scalable range 0…20 MΩ / 0…2 MΩ
– Dedicated probes and sensors
      With Factor probe C = 0.01, 0.1, 1 and 10
– 2 adjustable analog output 0/4-20 mA
– 3 relay outputs (NO contact)
– Wall mounting IP 65

Bamophox 322

– μS or MΩ built-in program
– Programmable scales:
      0 – 200 Ω up to 0 – 200 MΩ
      0 – 2 μS up to 0 – 20 mS
      TOR version: 0 – 2 mS up to 0 – 2000 mS
– Convenient probes:
      – cell factor of 10, 1, 0.1 or 0.01
      – and TOR sensor TCS 100
– Temperature compensation: Automatic or manual
– 2 analog outputs 0/4-20mA, galvanic insulated
– 3 relay outputs (Normally open contact)
– 1 input to switch the regulation on Stand-by
– 2 models:
      – Panel mounting 72 x 144
      – Wall mounting IP 65

OPTIONS :
      – RS 422 /J-BUS + LOGGER
      – Extension for 2nd measurement input