News

CS FA 415 dew point sensor

Article no: 0699 0415

The ideal dew point sensor for the monitoring of refrigeration dryers with analogue output 4…20 mA.

CS FA 416 condensate switch

Article no: 0699 0416

For reliable alarm signal in case of condensation with alarm relay and LED.

Tescom 44-1500 Series

TESCOM™ 44-1500 Series high flow/low regulator controls outlet pressures up to 600 PSIG [41 bar]. Large area piston provides accurate pressure control and cycle life superior to diaphragm sensed regulators when applied to heavy duty cycling. Features a segregated/captured vent for hydraulic or pneumatic media and available in two outlet spring ranges. Optional dome or air load versions for remote operation or for use with the TESCOM ER3000 Electropneumatic Controller for automation. Ideal for use in hydraulic or pneumatic testing applications.

JCT JES301EX

The JCT model JES301 Ex heated gas sample probe is used for the extraction and filtration of sample gases for use in continuous measurement analysis systems in EX Zone 1 or 2. The JES 301 Ex can be equipped with the same accessories as the JES 301 like back purge, calibration gas inlet with non return valve and different sampling tubes.

JCT 5 gas cooler

The JCT-5 Sample Gas Cooler is designed for extractive Gas Analysis Systems in ATEX rated Zone 1 or Zone 2. It effectively removes moisture from sample gases and provides a cooling of the sample down to 3°C.

It is based on the compressor cooling principle and utilises JCT’s established “Hot-Bypass” Technology which provides stable dew points, safe condensate removal and long operating life. It is capable of cooling up to 4 separate gas streams and condensate is removed via drain pumps or automatic drain units made of SS.

JCT gas cooler

The JCT series of sample gas coolers are designed to remove moisture from sample gases prior to measurement by moisture intolerant extractive gas analysers.
The coolers are based on the compressor cooling technology using high quality compressors and available in a number of options that include single or multiple gas paths, integrated peristaltic drain pumps and a range of various heat exchanger materials.
The JCT series coolers are available for non-hazardous area use and for EX area use with ATEX certificate.

JCT JC14 JC24 Peltier cooler

The new peltier coolers JC 14 and JC 24 provide a reliable gas conditioning prior to gas analysis. They have a short start-up time and are applicable for continous operation. The JC 14 and the JC 24 are upgradeable to turnkey gas conditioning units. Optionally available with: condensate detector, solenoid valve, calibration port, sample gas pump, stainless steel gas inlet.

JCT JCC Sample Gas Conditioning Unit

The JCC series gas conditioning units offer an autonomous sampling system for treatment of flue gases for extractive measurement systems. The units contain all the necessary components for moisture and particulate “clean-up” in a single enclosure.
The JCC series conditioning units are based on the proven JCT series range of coolers with the added benefit of the integration of sample gas pumps, condensers, condensate sensors, flow valves and fine dust filters thus allowing for reduced system build time or compact portable conditioning.
The JCC series of conditioners are available as 19” rack mounted and wall mounted versions or portable versions.