Dwyer MBLT series

• Ballast tanks; Ground water monitoring; Surface water monitoring; Dewatering; Down hole; Remediation and other environmental monitoring applications.

Specifications

  • Service: Compatible liquids.
  • Wetted Materials:
    Body and nose: 316 SS;
    Cable: Polyether polyurethane or ETFE;
    Seals: Fluoroelastomer;
    Label: Polyethylene polyamid.
  • Accuracy: ±0.25% or ±0.10% of FS.
  • Temperature Limits: -4 to 176°F (-20 to 80°C).
  • Compensated Temperature Limits: 0.25%: (0 to 70°C); 0.10%: (0 to 60°C).
  • Thermal Effect: 0.25%: ±0.45% FS TEB; 0.10%: ±0.30% FS TEB.
  • Pressure Limit: 2x FS.
  • Power Requirements: 10 to 33 VDC.
  • Output Signal: 4 to 20 mA DC 2- wire.
  • Response Time: < 50 ms.
  • Max Loop Resistance: 1000 Ω @ 30 VDC.
  • Electrical Connections: Wire pigtail.
  • Mounting Connection: Suspended below point being monitored.
  • Electrical Protection: Surge/lightning protected per EN61000-4-5, Class 5.
  • Weight: Body: 0.235 lb (0.107 kg); Cable: 0.037 lb (0.009 kg) per foot.
  • Agency Approval: CE.