Series H2

Specifications

 

  • Wetted Materials: 316 SS chamber with FEP diaphragm and Buna-N O-ring standard. Fluoroelastomer or EPDM O-ring optional.
  • Temperature Limit: 275°F (135°C). CSA approved: -20 to 90°C (-4 to 184°F).
  • Pressure Limit: 1500 psig (103 bar).
  • Enclosure Rating: UL listed explosion-proof, Class I, Groups B, C, and D. Class II Groups E, F, and G. Meets NEMA 4X (IP66). CSA optional. Class I, Groups B, C & D. Class II, Groups E, F, & G -20°C ≤ Tamb ≤ 75°C T6 [optional -20°C ≤ Tamb ≤ 40°C T5] Type 4.
  • Switch Type: Two SPDT snap switches.
  • Electrical Rating: 5 A @ 125/250 VAC, 5 A res., 3 A ind. @ 30 VDC. Gold contacts or 10 A switch optional.
  • Electrical Connections: 18 AWG, 18″ (460 mm) long.
  • Conduit Connection: 3/4″ female NPT.
  • Process Connection: 1/4″ female NPT.
  • Mounting Orientation: Any position.
  • Set Point Adjustment: Internal nut.
  • Weight: 2 lb (.9 kg).
  • Deadband: Approximately 10% of range.
  • Agency Approvals: CE, CSA, UL.