Tescom 44-5800 Series

Features & Benefits

  • Main Applications
  • Liquid Petroleum Analyzer
  • Petrochemical / Refinery Analyzer
  • Sampling Systems

Advanced Features

  • For worldwide use: Designed for 90-125 VAC / 190-230 VAC, 50/60 Hz
  • 4-20 mA analog output for remote temperature monitoring and data acquisition
  • Optional LCD temperature display
  • Optional heating capacity up to 400 watts for faster response to flow variations
  • Optional panel mounting
  • Advanced heat transfer technology
  • Single turn heater temperature control dial
  • CSA, ATEX, and IECEX Certification to T4 Rating
  • NACE MR0175/ISO 15156

Specifications

Pressure Rating

Maximum Inlet Pressure: 6,000 PSIG [414 bar]
Maximum Outlet Pressure:
0-25, 0-50, 0-100, 0-250, 0-500 PSIG [0-1.7, 0-3.4, 0-6.9, 0-17.2, 0-34.4 bar]

Material

Body: 316 Stainless Steel, Monel, or Hastelloy®
Seat: Vespel SP1®
Diaphragm & Spring: Elgiloy®, Hastelloy®
Remaining Parts: 316 Stainless Steel, Monel, or Hastelloy®

 

Operating Temperature

Maximum Media Temperature: 500°F [260°C]
Maximum Ambient Temperature: 149°F [65°C]
Minimum Ambient Temperature: -4°F [-20°C]
Heater Temperature Control: 270° Turn, 122°F to 572°F [50°C to 300°C]
Heater Temperature Analog Output: 176°F to 518°F [80°C to 270°C]

 

Port Size & Type

Electric & Steam: 1/4″ NPT

 

Flow Capacity

Cv = .02

 

Load Type

Spring

Weight

Electric: 6.3 lbs [2.9 kg]
Steam: 3.1 lbs [1.4 kg]