Features

 

• Magnetic Drive – water is sealed from entering register.

• Dry Dial won’t discolor or fade – hermetically sealed from the elements.

• Integral Strainer that protects meters from particulate damage.

• Pointer-Roller Indicator.

• Frost Resistant Body.

• Pulsed Output.

• Includes two mounting adapters (Couplings).

 

Specifications

 

Service: Water.

Flow Range: See Catalog page.

Wetted Materials: Body: brass, nylon, acetal; Couplings: brass; Measuring Chamber: Fluorocarbon (FKM), polyethylene, high impact polystyrene, ABS plastic.

Accuracy: Transitional Flow: ±5%, Nominal Flow: ±2% (see Instruction Manual).

Temperature Limit: 104°F (40°C).

Pressure Limit: 145 psi (10 bar).

Pressure Drop: See Instruction Manual.

Totalizing Display Maximum: 9,999,999 Counts.

Output Signal: Pulse output with frequency proportional to flow rate. Pulse Options: 0.1 gal, 1 gal, 10 gal, 100 gal per pulse (1L, 10L, 100L per pulse).

Electrical Rating: 0.01A @ 24VAC/DC.

Electrical Connections: Lead wires, 4.5 feet (1.5 meters) long.

Mounting Orientation: Horizontal.

Weight: See Dimensional Drawing.