Specifications
- Service: Compatible liquids.
- Wetted Materials:
Body and nose: 316 SS;
Cable: Polyether polyurethane or ETFE;
Seals: Fluoroelastomer;
Label: Polyethylene polyamid. - Accuracy: ±0.25% or ±0.10% of FS.
- Temperature Limits: -4 to 176°F (-20 to 80°C).
- Compensated Temperature Limits: 0.25%: (0 to 70°C); 0.10%: (0 to 60°C).
- Thermal Effect: 0.25%: ±0.45% FS TEB; 0.10%: ±0.30% FS TEB.
- Pressure Limit: 2x FS.
- Power Requirements: 10 to 33 VDC.
- Output Signal: 4 to 20 mA DC 2- wire.
- Response Time: < 50 ms.
- Max Loop Resistance: 1000 Ω @ 30 VDC.
- Electrical Connections: Wire pigtail.
- Mounting Connection: Suspended below point being monitored.
- Electrical Protection: Surge/lightning protected per EN61000-4-5, Class 5.
- Weight: Body: 0.235 lb (0.107 kg); Cable: 0.037 lb (0.009 kg) per foot.
- Agency Approval: CE.