The corrosion resistant 316L stainless steel wetted parts allow the Series 626 and 628 transmitters to measure the pressure in a multitude of processes from hydraulic oils to chemicals. The Series 626 and 628 are available in ranges of vacuum, compound to 5000 psi with a variety of optional outputs, process connections and electrical terminations to allow you to select the right transmitter for your application.
- Compressors
- Pumping Systems
- Irrigation System Pressure
- Fire Pump Control Pressure
- Industrial Process Monitoring
- Refrigerant Line Pressures on Air Handlers when used with optional Refrigerant Valve Depressor
- Trash Compaction Equipment
Features & Benefits
- Metal Conduit Housing Option
- Robust 316L SS Oil Filled Sensor
- Compact Design
Specifications
Service: Compatible gases and liquids.
Wetted Materials: Type 316L SS.
Accuracy: 626: 0.25% full scale; 626 absolute ranges: 0.5% full scale; 628: 1% full scale. (Includes linearity, hysteresis, and repeatability).
Temperature Limit: 0 to 200°F (-18 to 93°C).
Compensated Temperature Range: 0 to 175°F (-18 to 79°C).
Thermal Effect: ±0.02% FS/°F. (includes zero and span).
Pressure Limits: See Catalog page.
Power Requirements: 10 to 30 VDC.
Output Signal: 4 to 20 mA. Optional 0-5, 1-5 or 0-10.
Response Time: 50 msec.
Loop Resistance: 0-1300 ohms maximum for current. For voltage outputs, minimum load resistance: 2000 ohms.
Stability: 1.0% FS/year (Typ.).
Current Consumption: 38 mA (maximum).
Electrical Connections: Conduit Housing (-CH): terminal block; 1/2″ female NPT conduit. General Purpose Housing (-GH): cable or DIN EN175801-803-C.
Process Connection: 1/4″ male or female NPT and BSPT. Optional 1/8″ and 1/2″ male NPT available with GH housing only.
Enclosure Rating: NEMA 4X (IP66), Note: LED Version is not NEMA 4X (IP66) rated.
Mounting Orientation: Mount in any position.
Weight: 10 oz (283 g).
Agency Approvals: CE.