Features & Benefits
- Designed for agressive fluids
- Direct reading indicator
- From ND 50 up to ND 200 pipes
- Scale amplification from 2 to 10.
- Mounting in all positions
- Standardized with NF X 10-102 Norm
- Accuracy: ±2,5 % full scale
- Option: Electrical switch counter
Specifications
Measuring range : From 2 to 350 m3/h (see table on the back)
Accuracy : ±3 % (DB/IDP) ±4 % (DB/PDP)
Repeatability : ±0,3 % (DB/IDP) ±0,4 % (DB/PDP)
Scale amplification : 2 to 10 (DB/IDP) 2,5 to 10 (DB/PDP)
Max. temperature :
50°C – PVC
90°- PPH
120°C – PVDF
Max. pressure : 10 bar (20°C)
Materials
Diaphragm : PVC – PPH – PVDF
Flowmeter associated :
PVC (DB/IDP-V – DB/PDP-V)
Trogamid (DB/IDP-T – DB/PDP-T)
Polysulfon (DB/IDP-P – DB/PDP-P)
Float : PVDF
Supply line : PVC – PPH – PVDF
Stop valves : PVC – PPH – PVDF
O-Ring : EPDM (standard) – FPM (on request)
BORDA injector : PVC – PPH – PVDF
Options
For DB/IDP : Electrical switch ZE 951
For DB/PDP : Electrical switch ZE 951
Scales
Ranges indicated on the attached board, for DB/PDP flowmeters , are not contractual, but can be modified within
flow rate or diameter.
For DB IDP, minima flow rates have to be multiplied by 1,25.
Flow rates are indicated for PVC NP 10 pipes. In all events, the thickness and the exact interior diameter pipe have to be specified, so we may assure the specifications of the system
Pressure Loss
The loss of charge is the difference of pressure between upstream and dowmstream unrecoverable, create by the orifice. This loss of charge can be calculated on request.
Installation requirements
The installation conditions are useful to warrant a coherent measure in the range of precision.
The straight pipe lenghts upstream of the orifice, undermentioned, are given for indication.
Number of D
07 Simple elbow at 90°or T (flow rate by one branch)
17 2 elbows at 90°in 2 different plans
07 Reducing from 2 D to D on lenght 1,5 D to 3 D
07 Valve completly open (type membran valve or ball valve)
03 Downstream
The straight pipe lenght upstream depend to relation between intern pipe diameter (D), and the diameter orifice.
The exact lenght to respect for conserving the precision of whole measure are communicated after each case study.
Fixation flanges
The union nuts will be center with the flange of fixation as precisely as possible. The union nut arrest boards should be of the same diameter than intern diameter of tube, to avoid perturbation in liquid flow.
On resquest, we can deliver union nuts, flanges and screew.