Features & Benefits
- case diameter: 100 or 150 mm
- accuracy: Class 1
- scale ranges: From 0…0.6 bar to 0…1600 bar
- pressure limits during operation:
- Continuously: steady pressure up to F.S. value
- Fluctuating pressure: 90% of F.S. value
- Temporarily: 1.3 x F.S. value for ranges up to 60 bar or
- 1.15 x F.S. for ranges from 100 bar to 1600 bar
- temperature limits:
- Ambient: -40 to +60 °C (without liquid filling)
- and -20 to +60 °C (with liquid filling)
- Process: maximal fluid T° is 200 °C (without liquid filling)
- and 100 °C (with liquid filling)
- draft due to the temperature
- When the measuring system T° is different from the reference T° (+20 °C) the draft is 0.4% / 10 K of true scale value, as a maximum.
Specifications
process connection
Stainless steel: AISI 316 L
– Thread 1/2” BSP or NPT
– M20 x 1.5
Lower or back mounting
pressure element
Stainless steel: AISI 316 L
< 100 bar : C – type
> 100 bar : Helicoidal type
movement
Stainless steel: AISI 316 L
dial
White, black marks – Graduated scale length 270° angle
pointer
Black aluminium pointer, adjustable
case and ring
Stainless steel: AISI 304
Pressure relief disc (25 mm) on the rear back
Filling plug on the top (used as a vent hole for ranged instruments up to 16 bar)
Bayonet type ring
window
Safety glass 4 mm thick
sealing
Neoprene gasket
ingress protection
IP 65 acc. EN 60529 / IEC 529
Options
- Other type connections
- Case and ring AISI 316 L
- Front or rear flange
- Silicone oil case filled (ambient temperature from -40 to +60 °C)
- Other filling liquids on request
- Electric contacts
- Diaphragm seals
- Oxygen application: grease free measuring system
- Scale in °C for cooling fluids
- Accuracy class 0.6
- ATEX certification Ex II 2 GD c
- Accessories.