Features & Benefits
- Regulating Range from -10 to 4000 mbar
- Sizes DN15 to DN 100 (1/2” to 4”)
- Pressure Resistance 10 bar
- Back Pressure Resistance up to 4000 mbar
- Withstands Full Vacuum
- Stainless Steel Regulators
- Hastelloy Regulators
- PVDF Regulators
- Clean and Sterile Regulators
- Maintenance Friendly
- ATEX II 2GD IIC
Specifications
Inlet pressure : 16 bar
(10 bar for DN 80/DN100 and for PVDF Regulators)
Back pressure resistance : 4 bar
Regulating range of springs : -200 to +400 mbar
Pilot regulating range : Up to 4000 mbar
Max. vacuum : Withstands full vacuum
Max. temp. FFKM (Kalrez®) : -20°C to +160°C
Max. temp. FPM (Viton®) : -20°C to +120°C
Tightness / Adjustment:
Seat tightness acc. to EN 12266-1, leaking rate A, P12
Flow capacity for adjustment
DN 15 /1/2” : 0.5 Nm3/h
DN 25 / 1” : 1 Nm3/h
DN 50 / 2” : 2 Nm3/h
DN 80 / 3” : 5 Nm3/h
DN 100 / 4” : 5 Nm3/h
Certificates
According to Pressure Equipment Directive PED 97/23/EG
Conformity statement QS 04 ATEX 2006 : II 2GD IIC
Statement of Compliance : US.FDA 21 CFR
Work Certificate : EN10204 3.1B
Standard Design
Application: For processes in the chemical-pharmaceutical industries, without substandard requirement.
Example of uses:
– Protection against explosion.
– Prevention of building an explosive mixture of gas by exchanging the atmospheric air with an inert gas.
Mounting form: Inline- and angle pattern
Surface: Without special treatment
Complete drain: No
Clean Design
Application: For procedures in the pharmaceutical industries and food production with increased requirements concerning surface treatment, dead space and cleaning.
Example of uses :
– Protection against oxidation.
– The replacement of the atmospheric air by an inert gas prevents the building of an oxidizing ambiance.
Mounting form: Angle pattern
Internal space: Rounded edges, minimized dead space Surface Roughness for areas in contact with media < Ra 0.6 μm, internal and external electro polishing as option.
Complete drain: Yes
Sterile Design
Application: Duties in the pharmaceutical industries and biotechnology with extremely high degree requirements to sterility.
Example of uses: All processes and procedures in sterile quality.
Mounting form: Angle pattern
Internal space: Separated process- and control space, no dead space.
Surface: Areas in contact with media < Ra 0.6 μm and electro polished, external electro polishing as option.
Complete drain: Yes
CIP connection: Yes